» Articles » PMID: 10711892

A Comparison of Tangent Screen, Goldmann, and Humphrey Perimetry in the Detection and Localization of Occipital Lesions

Overview
Journal Ophthalmology
Publisher Elsevier
Specialty Ophthalmology
Date 2000 Mar 11
PMID 10711892
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To compare manual kinetic perimetry with tangent screen and Goldmann techniques and automated static perimetry with the Humphrey Field Analyzer in the detection and localization of occipital lobe lesions.

Design: Prospective consecutive comparative case series.

Participants: Twelve patients with well-defined occipital lobe infarcts on magnetic resonance (MR) imaging were studied.

Main Outcome Measures: The patients were tested by tangent screen, Goldmann, and Humphrey perimetry (central 30-2 threshold program). The three visual fields were compared and correlated with MR images.

Results: All three perimetric techniques detected the presence of postchiasmal lesions. However, localization of lesions differed with perimetric technique. Visual fields obtained from tangent screen and Goldmann perimetry were similar and corresponded well with the location of lesions on MR images in all 12 patients. Humphrey perimetry inaccurately localized the lesion to the proximal part of the postchiasmal pathway by revealing incongruous fields in two patients, failed to detect sparing of the posterior occipital cortex or occipital pole in four patients, and estimated a larger extent of damage in one patient when compared with MR images and manual perimetry.

Conclusions: All three perimetric techniques are satisfactory screening tests to detect occipital lesions. However, tangent screen and Goldmann perimetry provide information about the location and extent of lesions that is more consistent with prevailing knowledge of the effects of the lesion in the postgeniculate visual pathway.

Citing Articles

Alternative perimetric tests for patients with drug-resistant epilepsy.

Thakur M, Gattu A, Murthy J, Satgunam P PLoS One. 2025; 20(2):e0318025.

PMID: 39992979 PMC: 11849900. DOI: 10.1371/journal.pone.0318025.


Visual Field Tests: A Narrative Review of Different Perimetric Methods.

Rai B, Sabeti F, Carle C, Maddess T J Clin Med. 2024; 13(9).

PMID: 38730989 PMC: 11084906. DOI: 10.3390/jcm13092458.


Comparison of unifocal, flicker, and multifocal pupil perimetry methods in healthy adults.

Portengen B, Porro G, Imhof S, Naber M J Vis. 2022; 22(9):7.

PMID: 35998063 PMC: 9424968. DOI: 10.1167/jov.22.9.7.


Comparative evaluation of Octopus semi-automated kinetic perimeter with Humphrey and Goldmann perimeters in neuro-ophthalmic disorders.

Bhaskaran K, Phuljhele S, Kumar P, Saxena R, Angmo D, Sharma P Indian J Ophthalmol. 2021; 69(4):918-922.

PMID: 33727459 PMC: 8012927. DOI: 10.4103/ijo.IJO_1266_20.


Visual Field Progression in Retinitis Pigmentosa.

Xu M, Zhai Y, MacDonald I Invest Ophthalmol Vis Sci. 2020; 61(6):56.

PMID: 32589198 PMC: 7415895. DOI: 10.1167/iovs.61.6.56.