» Articles » PMID: 10678277

Reproducibility of Heart Rate Measured in the Clinic and with 24-hour Intermittent Recorders

Overview
Journal Am J Hypertens
Date 2000 Mar 11
PMID 10678277
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

This study was undertaken to assess the reproducibility of office versus ambulatory heart rates in 839 hypertensive subjects participating in the Hypertension and Ambulatory Recording Venetia Study (HARVEST). A 24-hour heart rate was recorded twice; this procedure was repeated three months later. Reproducibility was better for ambulatory than for office measurement, and was greater for 24-hour than for daytime heart rate, and lowest for night-time heart rate. Reproducibility of office heart rate was impaired above 85 bpm, and was poorer in subjects with more severe office hypertension. A small but significant decrease in average daytime (-1 bpm, P < 0.0001) and virtually no change in night-time heart rate (-0.3 bpm, NS) were observed at repeat recording. Heart rate reproducibility indices were related to the extent of the heart rate and blood pressure white-coat effect, but did not vary according to age, gender, body mass index, day-night blood pressure difference, or alcohol or tobacco use. Results indicate that heart rate recorded over the 24 hours has a better reproducibility than office heart rate, and could thus be a better prognostic indicator than traditional measurement of resting heart rate in the hospital setting.

Citing Articles

Unattended Office Heart Rate Measurement: A New Challenge in Clinical Practice?.

Palatini P J Clin Hypertens (Greenwich). 2024; 26(11):1310-1312.

PMID: 39327795 PMC: 11555540. DOI: 10.1111/jch.14909.


High blood pressure with elevated resting heart rate: a high risk "Sympathetic" clinical phenotype.

Grassi G, DellOro R, Bombelli M, Cuspidi C, Quarti-Trevano F Hypertens Res. 2023; 46(10):2318-2325.

PMID: 37500715 DOI: 10.1038/s41440-023-01394-9.


Wearable sensors enable personalized predictions of clinical laboratory measurements.

Dunn J, Kidzinski L, Runge R, Witt D, Hicks J, Schussler-Fiorenza Rose S Nat Med. 2021; 27(6):1105-1112.

PMID: 34031607 PMC: 8293303. DOI: 10.1038/s41591-021-01339-0.


Real-world heart rate norms in the Health eHeart study.

Avram R, Tison G, Aschbacher K, Kuhar P, Vittinghoff E, Butzner M NPJ Digit Med. 2019; 2:58.

PMID: 31304404 PMC: 6592896. DOI: 10.1038/s41746-019-0134-9.


Heart rate in patients with reduced ejection fraction: relationship between single time point measurement and mean heart rate on prolonged implantable cardioverter defibrillator monitoring.

Habal M, Nanthakumar K, Austin P, Freitas C, Labos C, Lee D BMC Cardiovasc Disord. 2018; 18(1):17.

PMID: 29385998 PMC: 5793357. DOI: 10.1186/s12872-018-0751-2.