Mechanical Validation of Whole Bone Composite Tibia Models

Overview
Journal J Biomech
Specialty Physiology
Date 2000 Feb 15
PMID 10673111
Citations 51
Authors
Affiliations
Soon will be listed here.
Abstract

Composite synthetic models of the human tibia have recently become commercially available as substitutes for cadaveric specimens. Their use is justified by the advantages they offer as a substitute for real tibias. The present investigation concentrated on an extensive experimental validation of the mechanical behaviour of the whole bone composite model, compared to human specimens for different loading conditions. The stiffness of the tibias was measured with a torsional load applied along the long axis, and with a bending load applied both in the latero-medial and in the antero-posterior direction. The bending stiffness of the composite tibias matched well with that of the cadaveric specimens. This was not true for the torsional stiffness. In fact, the composite tibias were much stiffer than the cadaveric specimens, possibly due to the structure of the reinforcement material. The inter-specimen variability for the composite tibias was much lower than that for the cadaveric specimens. Thus, it seems that the composite tibias are suitable to replace cadaveric specimens for certain types of test, whereas they might be unsuitable for others, depending on the loading regimen.

Citing Articles

Ex Vivo Biomechanical Bone Testing of Pig Femur as an Experimental Model.

Kulic M, Bagavac P, Bekic M, Krstulovic-Opara L Bioengineering (Basel). 2024; 11(6).

PMID: 38927808 PMC: 11200541. DOI: 10.3390/bioengineering11060572.


Design of osteosynthesis plate for detecting bone union using wire natural frequency.

Chancharoen P, Tangpornprasert P, Amarase C, Tantavisut S, Virulsri C Sci Rep. 2024; 14(1):12569.

PMID: 38822126 PMC: 11143194. DOI: 10.1038/s41598-024-63530-w.


Compliant Intramedullary Stems for Joint Reconstruction.

Mccullough J, Peterson B, Upfill-Brown A, Hardin T, Hopkins J, SooHoo N IEEE J Transl Eng Health Med. 2024; 12:314-327.

PMID: 38486844 PMC: 10939320. DOI: 10.1109/JTEHM.2024.3365305.


Busch-Hoffa fracture: A systematic review.

Rabelo J, Pires R, Casas E, Cimini Jr C Medicine (Baltimore). 2023; 102(48):e36161.

PMID: 38050206 PMC: 10695599. DOI: 10.1097/MD.0000000000036161.


Biomechanical analysis of different THA cementless femoral stem designs in physiological and osteoporotic bone during static loading conditions.

Formica M, Zanirato A, Bori E, Revetria T, Ditting J, Innocenti B Arch Orthop Trauma Surg. 2023; 144(2):917-926.

PMID: 37796284 DOI: 10.1007/s00402-023-05080-w.