» Articles » PMID: 10601708

Changes to Low-frequency Components of the TEOAE Following Acoustic Trauma to the Base of the Cochlea

Overview
Journal Hear Res
Date 1999 Dec 22
PMID 10601708
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Several studies have shown that acoustic trauma to the base of the cochlea can result in loss of transient-evoked otoacoustic emission (TEOAE) energy at frequencies much lower than those affected in the audiogram. We have extended these studies to show that the low-frequency emission energy was substantially affected if the transient stimulus included frequencies within the range affected by the trauma, otherwise the change observed was small. In keeping with the suggestion that TEOAEs are predominantly comprised of intermodulation distortion energy (Yates and Withnell, Hear. Res. 136 (1999) 49-64), trauma to the basal region of the cochlea was found to affect emission energy across a broad frequency range in response to a wide-band acoustic stimulus. Further, group delay measurements demonstrated that the dominant contribution to the TEOAE originated from the basal region of the cochlea.

Citing Articles

A Variable-Stimulus Distortion Product Otoacoustic Emission Screening Method to Match Cochlear Place-Specific Properties.

Stiepan S, Dhar S Ear Hear. 2024; 46(2):421-432.

PMID: 39407360 PMC: 11832347. DOI: 10.1097/AUD.0000000000001594.


The Origin Along the Cochlea of Otoacoustic Emissions Evoked by Mid-Frequency Tone Pips.

Goodman S, Lefler S, Lee C, Guinan Jr J, Lichtenhan J J Assoc Res Otolaryngol. 2024; 25(4):363-376.

PMID: 38937327 PMC: 11349973. DOI: 10.1007/s10162-024-00955-0.


Utility of otoacoustic emissions and olivocochlear reflex in predicting vulnerability to noise-induced inner ear damage.

Blioskas S, Tsalighopoulos M, Psillas G, Markou K Noise Health. 2018; 20(94):101-111.

PMID: 29785975 PMC: 5965001. DOI: 10.4103/nah.NAH_61_17.


Profiles of Stimulus-Frequency Otoacoustic Emissions from 0.5 to 20 kHz in Humans.

Dewey J, Dhar S J Assoc Res Otolaryngol. 2016; 18(1):89-110.

PMID: 27681700 PMC: 5243260. DOI: 10.1007/s10162-016-0588-2.


Tuning of SFOAEs Evoked by Low-Frequency Tones Is Not Compatible with Localized Emission Generation.

Charaziak K, Siegel J J Assoc Res Otolaryngol. 2015; 16(3):317-29.

PMID: 25813430 PMC: 4417092. DOI: 10.1007/s10162-015-0513-0.