Erosion of Artificial Endothelia in Vitro by Pulsed Ultrasound: Acoustic Pressure, Frequency, Membrane Orientation and Microbubble Contrast Agent Dependence
Overview
Authors
Affiliations
The erosion of cells from fibroblast monolayers simulating the vascular endothelium by 20 micros pulses of ultrasound at 500 Hz PRF was studied in relation to the peak negative acoustic pressure (P-; 0.0-2.5 MPa), ultrasound (US) frequency (1.0, 2.1 or 3.5 MHz), orientation of the monolayer (i.e., simulating the sites of ultrasound entry/exit from a blood vessel) and the presence or absence of a microbubble contrast agent (3 Vol% Albunex). The a priori hypotheses were that erosion of the monolayers would: 1. arise due to insonation treatment, 2. arise as a consequence of cavitation activity and, thus, increase with increasing P- at constant frequency, and decrease with increasing frequency at constant P-, 3. be significantly increased by the presence of a microbubble contrast agent, and 4. have a weak dependence on monolayer orientation. The data support these hypotheses. Under the most severe exposure conditions used, most of the affected cells appeared to have been lysed; however, a substantial number of viable cells were dislodged from the monolayer surface.
Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.
Hynynen K, Jones R Phys Med Biol. 2016; 61(17):R206-48.
PMID: 27494561 PMC: 5022373. DOI: 10.1088/0031-9155/61/17/R206.
Modelling cavitation erosion using fluid-material interaction simulations.
Chahine G, Hsiao C Interface Focus. 2015; 5(5):20150016.
PMID: 26442140 PMC: 4549842. DOI: 10.1098/rsfs.2015.0016.
Effects of ultrasound and ultrasound contrast agent on vascular tissue.
Wood S, Antony S, Brown R, Chen J, Gordon E, Hitchins V Cardiovasc Ultrasound. 2012; 10:29.
PMID: 22805356 PMC: 3493263. DOI: 10.1186/1476-7120-10-29.
Insonation of targeted microbubbles produces regions of reduced blood flow within tumor vasculature.
Hu X, Kheirolomoom A, Mahakian L, Beegle J, Kruse D, Lam K Invest Radiol. 2012; 47(7):398-405.
PMID: 22659591 PMC: 3552613. DOI: 10.1097/RLI.0b013e31824bd237.
A tissue phantom for visualization and measurement of ultrasound-induced cavitation damage.
Maxwell A, Wang T, Yuan L, Duryea A, Xu Z, Cain C Ultrasound Med Biol. 2010; 36(12):2132-43.
PMID: 21030142 PMC: 2997329. DOI: 10.1016/j.ultrasmedbio.2010.08.023.