Lens Autofluorescence and Light Scatter in Relation to the Lens Opacities Classification System, LOCS III

Overview
Specialty Ophthalmology
Date 1999 Nov 7
PMID 10551289
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare values of the human lens autofluorescence and back light scatter measurements with the improved Lens Opacities Classification System, LOCS III.

Methods: We measured autofluorescence and back light scatter of the lens from 122 smoking males aged 57 to 76 years who participated in a cancer prevention study. The retroillumination and slit-lamp photographs of the lenses were graded according to LOCS III by the Center for Ophthalmic Research in Boston. Lens fluorometry was carried out with a previously described technique using blue-green (495 nm/520 nm) autofluorescence range. Interzeag Lens Opacity Meter 701 was used for light scatter measurements.

Results: LOCS III nuclear opalescence and color grades were statistically significantly correlated with lens autofluorescence as well as with light scatter values. The lens transmission index of autofluorescence measurements showed the highest correlation with the nuclear color (r = -0.71; p < 0.0001) and the light scatter value with nuclear opalescence (r = 0.64; p < 0.0001). There was no correlation between autofluorescence measurements and LOCS III grades of cortical or posterior subcapsular cataract. A weak relation could be found between the grades of cortical cataract and light scatter values.

Conclusions: The lens fluorometry provides a practical clinical technique to evaluate the yellow coloration and opalescence of the human lens nucleus. It may be a useful additional tool together with a subjective grading system in the follow-up of optical changes occurring in the nuclear region of the lens.

Citing Articles

Visual Acuity Prior to Cataract Surgery and Risk of Retinal Detachment - A Population-Based Study.

Thylefors J, Jakobsson G, Zetterberg M, Sheikh R Clin Ophthalmol. 2023; 17:1975-1980.

PMID: 37465271 PMC: 10350414. DOI: 10.2147/OPTH.S410585.


Macular Pigment Response to Lutein, Zeaxanthin, and Meso-zeaxanthin Supplementation in Open-Angle Glaucoma: A Randomized Controlled Trial.

Loughman J, Loskutova E, Butler J, Siah W, OBrien C Ophthalmol Sci. 2022; 1(3):100039.

PMID: 36247822 PMC: 9562333. DOI: 10.1016/j.xops.2021.100039.


Long-term development of lens fluorescence in a twin cohort: Heritability and effects of age and lifestyle.

Bjerager J, Dabbah S, Belmouhand M, Kessel L, Hougaard J, Rothenbuehler S PLoS One. 2022; 17(5):e0268458.

PMID: 35617652 PMC: 9135443. DOI: 10.1371/journal.pone.0268458.


The Influence of Intraocular Lens Implantation and Alterations in Blue Light Transmittance Level on the Brain Functional Network Architecture Reorganization in Cataract Patients.

Sobczak A, Bohaterewicz B, Fafrowicz M, Domagalik A, Beldzik E, Oginska H Brain Sci. 2021; 11(11).

PMID: 34827400 PMC: 8615544. DOI: 10.3390/brainsci11111400.


Lens fluorescence and skin fluorescence in the Copenhagen Twin Cohort Eye Study: Covariates and heritability.

Bjerager J, Dabbah S, Belmouhand M, Rothenbuehler S, Sander B, Larsen M PLoS One. 2021; 16(9):e0256975.

PMID: 34499644 PMC: 8428679. DOI: 10.1371/journal.pone.0256975.