» Articles » PMID: 10548787

Visualization of Aortic Valve Leaflets Using Black Blood MRI

Overview
Date 1999 Nov 5
PMID 10548787
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Although magnetic resonance imaging (MRI) is capable of imaging various physiological parameters associated with the heart valves, it has generally been difficult to visualize the valve leaflets directly. The aortic valve was imaged in 120 patients referred for cardiac MRI to assess myocardial volumes or mass. The average patient age was 37 and ranged from 9 to 75 years. Heart rate ranged from 43 to 100 bpm. Imaging was performed on a 1.5 T scanner equipped with enhanced gradients and a cardiac phased-array coil. A double inversion recovery fast spin-echo sequence was used to acquire short-axis images of the aortic valve in a breath-hold (15 +/- 3 seconds). All three leaflets of the aortic valve were seen in 102 of 120 studies (85%). Two leaflets were detected in another 15 subjects. No leaflets were seen in three individuals. Seven cases of a bicuspid or thickened aortic valves were clearly distinguished from normal valves. The signal-to-noise ratio of aortic leaflets (14 +/- 5) was significantly higher than that of the residual blood signal in the aortic root (7 +/- 4, P < 0.001). MR images showed the aortic valve leaflets in a high fraction of people with suspected normal aortic valves and detected seven cases of abnormal aortic valves. The potential of MRI to study both the anatomic and functional consequences of valvular heart disease warrants further study. J. Magn. Reson. Imaging 1999;10:771-777.

Citing Articles

Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation.

Moghari M, Barthur A, Amaral M, Geva T, Powell A Magn Reson Med. 2017; 80(1):181-189.

PMID: 29222852 PMC: 5876089. DOI: 10.1002/mrm.27021.


Imaging of cardiovascular complications in patients with systemic lupus erythematosus.

Lin K, Lloyd-Jones D, Li D, Liu Y, Yang J, Markl M Lupus. 2015; 24(11):1126-34.

PMID: 26038342 PMC: 4567427. DOI: 10.1177/0961203315588577.


Spectrum of aortic valve abnormalities associated with aortic dilation across age groups in Turner syndrome.

Olivieri L, Baba R, Arai A, Bandettini W, Rosing D, Bakalov V Circ Cardiovasc Imaging. 2013; 6(6):1018-23.

PMID: 24084490 PMC: 4407276. DOI: 10.1161/CIRCIMAGING.113.000526.


Controversies in cardiovascular MR imaging: reasons why imaging myocardial T2 has clinical and pathophysiologic value in acute myocardial infarction.

Arai A, Leung S, Kellman P Radiology. 2012; 265(1):23-32.

PMID: 22993218 PMC: 3447177. DOI: 10.1148/radiol.12112491.


Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique--comparison of an intravascular and extravascular contrast agent.

Makowski M, Wiethoff A, Jansen C, Uribe S, Parish V, Schuster A J Cardiovasc Magn Reson. 2012; 14:53.

PMID: 22849703 PMC: 3438073. DOI: 10.1186/1532-429X-14-53.