Direct Determination of Bisphenol A and Nonylphenol in River Water by Column-switching Semi-microcolumn Liquid Chromatography/electrospray Mass Spectrometry

Overview
Specialty Chemistry
Date 1999 Oct 19
PMID 10523782
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

A rapid and sensitive analytical method based on column-switching semi-microcolumn high-performance liquid chromatography (HPLC) with electrospray mass spectrometry was developed for determining trace levels of bisphenol A (2,2-bis(4-hydroxyphenyl)propane) and nonylphenol (4-nonylphenol) in river water. An aliquot of sample solution was directly injected into the precolumn packed with Capcellpak MF-Ph for sample cleanup and enrichment. The compounds of interest were then transferred to a C-18 analytical column for main separation through a change in flow path by a programmed switching valve. Bisphenol A, nonylphenol, and interfering substances were satisfactorily separated with a simple gradient elution complete within 35 min. Detection of their deprotonated molecules was conducted in negative ion mode. A reduced flow rate (100 &mgr;L/min) optimized for the narrow bore column was found advantageous in obtaining a high degree of sensitivity during electrospray detection. The influence of carrier additives on sensitivity was also examined. This method produced detection limits of 0.5 ng/mL for bisphenol A and 10 ng/mL for nonylphenol (signal-to-noise ratio 3). Calibration curves were observed in the range of 2.5-50 ng/mL (r(2) = 0.999) for bisphenol A and 50-500 ng/mL (r(2) = 0.998) for nonylphenol. Recoveries of the compounds from spiked distilled water and river water were 99.7-138.5% with a relative standard deviation (RSD) ranging from 2.2-9.7%. Copyright 1999 John Wiley & Sons, Ltd.

Citing Articles

Nitrogen-doped carbon quantum dots for fluorescence detection of Cu and electrochemical monitoring of bisphenol A.

Wu X, Wu L, Cao X, Li Y, Liu A, Liu S RSC Adv. 2022; 8(36):20000-20006.

PMID: 35541682 PMC: 9080772. DOI: 10.1039/c8ra03180k.


Novel Class of Isoxazole-Based Gelators for the Separation of Bisphenol A from Water and Cleanup of Oil Spills.

Singh S, Saha P, Dey S, Nandi S ACS Omega. 2020; 5(15):8613-8618.

PMID: 32337424 PMC: 7178365. DOI: 10.1021/acsomega.0c00004.


Solvent Front Position Extraction with Semi-Automatic Device as a Powerful Sample Preparation Procedure Prior to Quantitative Instrumental Analysis.

Klimek-Turek A, Jaglinska K, Imbierowicz M, Dzido T Molecules. 2019; 24(7).

PMID: 30959894 PMC: 6480151. DOI: 10.3390/molecules24071358.


Parent bisphenol A accumulation in the human maternal-fetal-placental unit.

Schonfelder G, Wittfoht W, Hopp H, Talsness C, Paul M, Chahoud I Environ Health Perspect. 2002; 110(11):A703-7.

PMID: 12417499 PMC: 1241091. DOI: 10.1289/ehp.110-1241091.