We have developed a new technique to resect hepatic parenchyma without inflow occlusion by using the Cavitron Ultrasonic Surgical Aspirator (CUSA) and bipolar cautery with a saline irrigation system. The significance of this method in hepatectomy was analyzed in comparison with historical control of hepatectomy using Pringle's maneuver. An ordinary bipolar cautery was remodeled with an infusion line to bring saline droplets down the inner surface of one arm of the tweezers through an opening about 1.5 cm proximal to its tip. The optimal flow rate of saline was approximately one drop per second. The power of bipolar cautery was adjusted to 50 watts. When the tweezer blades were approximated to 1 or 2 mm, saline droplets were directed to the tip of tweezers and could be immediately evaporated. After sonicating parenchymal cells, the tissue of small branches of Glisson's tree or small tributaries of the hepatic vein were coagulated by bipolar cautery. The coagulated cords were then easily cut by scissors. The impact of this technique on ordinary liver resections was evaluated by analyzing the postoperative clinical course in relation to the hepatic functional reserve necessary for major hepatectomy, duration of hepatectomy, and intraoperative blood loss. Hepatic resection without vascular occlusion using this technique could decrease the morbidity in patients who have less hepatic functional reserve. It could also decrease intraoperative blood loss. This new technique effectively decreased the surgical load of the remnant liver during parenchymal resection by avoiding ischemic stress. Consequently it extends the safety limits of major hepatectomy.

Citing Articles

Robotic Anatomical Liver Resection for Segment 7 Lesions Utilizing Saline-Linked Cautery (SLiC) Method.

Fujikawa T, Uemoto Y Cureus. 2024; 16(10):e71537.

PMID: 39559640 PMC: 11570873. DOI: 10.7759/cureus.71537.


An Efficient Saline-Linked Cautery (SLiC) Method for Robotic Liver Parenchymal Transection Using Simultaneous Activation of Saline-Linked Cautery and Robotic Suctioning: Detailed Technical Aspects and Short-Term Outcomes.

Fujikawa T, Uemoto Y, Harada K, Matsuoka T Cureus. 2024; 16(3):e57219.

PMID: 38686234 PMC: 11057683. DOI: 10.7759/cureus.57219.


The Impact of Modified Two-Surgeon Technique for Laparoscopic Liver Resection on the Training of Surgeons-in-Training.

Fujikawa T, Uemoto Y, Matsuoka T Cureus. 2023; 15(5):e38865.

PMID: 37313109 PMC: 10260271. DOI: 10.7759/cureus.38865.


Intrahepatic Glissonean Approach for Robotic Anatomical Liver Resection of Segment 7 Using the Saline-Linked Monopolar Cautery Scissors (SLiC-Scissors) Method: A Technical Case Report With Videos.

Fujikawa T, Uemoto Y, Matsuoka T Cureus. 2023; 15(5):e38470.

PMID: 37273316 PMC: 10236908. DOI: 10.7759/cureus.38470.


Non-Stick Liver Parenchymal Transection With Saline-Linked Bipolar Clamp-Crush Technique in Robotic Liver Resection.

Kajiwara M, Fujikawa T, Naito S, Sasaki T, Nakashima R, Hasegawa S Cureus. 2023; 15(3):e36401.

PMID: 37090277 PMC: 10114974. DOI: 10.7759/cureus.36401.