» Articles » PMID: 10509243

Abdominal Aortic Aneurysm. Detection of Multilevel Vascular Pathology by Time-resolved Multiphase 3D Gadolinium MR Angiography: Initial Report

Overview
Journal Invest Radiol
Specialty Radiology
Date 1999 Oct 6
PMID 10509243
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To evaluate multiphasic 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for detection of vascular pathology at multiple levels of the aorta and iliac arteries.

Methods: In 18 patients with abdominal aortic aneurysm (n = 13), dissection (n = 3), or both (n = 2), multiphase 3D-Gd-MRA was performed acquiring five consecutive (6.8 seconds) 3D data sets in a single breath-hold. In each of the five time-resolved phases, vessel visibility of the abdominal aortic branches and iliac arteries was assessed. The extent of vessel involvement by the aneurysm or dissection seen on multiphase 3D-Gd-MRA was compared with standard imaging and surgical findings. Digital subtraction angiography was available for comparison in 4 cases, CT angiography in 10 cases.

Results: Due to the delayed filling of the aortic aneurysm, the proximal aortic branches and the aneurysm neck demonstrated an inversely related enhancement compared with the distal abdominal and iliac vessels (P < 0.001). Review of all five phases of multiphase 3D-Gd-MRA allowed optimal visualization of each vessel segment without any artifacts due to parenchymal or venous overlay. In dissections, review of three phases was required (P < 0.001) for diagnostic evaluation of the true and false lumens. Substantially more vessel involvement was detected on multiphase 3D-Gd-MRA; this was surgically confirmed in 10 of 11 cases and affected therapy management in 11 of 18 cases.

Conclusions: Multiphase 3D-Gd-MRA is a convenient, robust, and safe technique for presurgical anatomic mapping of complex aortic aneurysms and dissections.

Citing Articles

Usefulness of time-resolved MR angiography in spinal dural arteriovenous fistula (SDAVF)-a systematic review and meta-analysis.

Wojtowicz K, Przepiorka L, Maj E, Kujawski S, Marchel A, Kunert P Neurosurg Rev. 2023; 47(1):9.

PMID: 38072856 PMC: 10710966. DOI: 10.1007/s10143-023-02242-7.


Time-Resolved Three-Dimensional Contrast-Enhanced Magnetic Resonance Angiography in Patients with Chronic Expanding and Stable Aortic Dissections.

Trojan M, Rengier F, Kotelis D, Muller-Eschner M, Partovi S, Fink C Contrast Media Mol Imaging. 2018; 2017:5428914.

PMID: 29317855 PMC: 5727560. DOI: 10.1155/2017/5428914.


Time-resolved contrast-enhanced MR angiography: Value of hemodynamic information in the assessment of vascular diseases.

Maj E, Cieszanowski A, Rowinski O, Wojtaszek M, Szostek M, Tworus R Pol J Radiol. 2012; 75(1):52-60.

PMID: 22802762 PMC: 3389854.


Gadofosveset-enhanced magnetic resonance angiography.

Goyen M Vasc Health Risk Manag. 2008; 4(1):1-9.

PMID: 18629367 PMC: 2464762. DOI: 10.2147/vhrm.2008.04.01.1.


[Vascular and parenchymal diseases of the kidney].

Michaely H, Reichert M, Weckbach S, Schoenberg S Radiologe. 2008; 48(2):185-200.

PMID: 18236024 DOI: 10.1007/s00117-008-1616-y.