» Articles » PMID: 10504624

Autotransfusion in Coronary Artery Bypass Grafting: Disparity in Laboratory Tests and Clinical Performance

Overview
Date 1999 Oct 3
PMID 10504624
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Autotransfusion during and after cardiac surgery is widely performed, but its effects on coagulation, fibrinolysis, and inflammatory response have not been known in detail.

Methods: Hemostatic and inflammatory markers were extensively studied in 40 coronary artery bypass patients undergoing a consistent intraoperative and postoperative autotransfusion protocol. An identical autotransfusion protocol was applied to 4916 consecutive coronary patients and the overall clinical results were evaluated in this large patient population.

Results: The autologous blood pooled before bypass remained nearly inactivated after storage. A slight elevation of thrombin-antithrombin complex and prothrombin fragment 1.2, as well as plasmin/alpha(2)-antiplasmin complex was found in the content of the extracorporeal circuit after surgery, indicating thrombin formation and fibrinolytic activity. Also some increase of beta-thromboglobulin was present. In the mediastinal shed blood, complete coagulation, as evidenced by the absence of fibrinogen, had taken place and all parameters described above were extremely elevated. However, no thrombin activity was detected. As for the inflammatory response, moderately increased levels of complement activation products, terminal complement complex, and interleukin-6 traced in the extracorporeal circuit reached very high levels in mediastinal shed blood. Autotransfusion of the residual extracorporeal circuit blood and the mediastinal drainage was followed by elevation of most of these markers in circulating plasma. On the other hand, no correlating harmful effects were recorded in the study patients or in the consecutive 4916 patients. Coagulation disturbances were rare and allogeneic transfusions were required in fewer than 4% of all patients.

Conclusions: The hemostatic and immunologic systems were moderately activated in the autologous blood remaining in the extracorporeal circuit, whereas the mediastinal shed blood was highly activated in all aspects. However, autotransfusion had no correlating clinical side-effects and the subsequent exposure to allogeneic blood products was minimal.

Citing Articles

The effects on coagulation of the reinfusion of unprocessed residual blood from the cardiopulmonary bypass.

Iyer Y, Hayward P, McNicol L, Weinberg L BMC Res Notes. 2016; 9:61.

PMID: 26843072 PMC: 4739327. DOI: 10.1186/s13104-016-1868-y.


Coronary artery surgery: cardiotomy suction or cell salvage?.

Lau K, Shah H, Kelleher A, Moat N J Cardiothorac Surg. 2007; 2:46.

PMID: 17961227 PMC: 2173896. DOI: 10.1186/1749-8090-2-46.


Improved coagulation and blood conservation in the golden hours after cardiopulmonary bypass.

Beckmann S, Carlile D, Bissinger R, Burrell M, Winkler T, Shely W J Extra Corpor Technol. 2007; 39(2):103-8.

PMID: 17672193 PMC: 4680662.