» Articles » PMID: 10470468

Predictors of Diffuse-type In-stent Restenosis After Coronary Stent Implantation

Overview
Date 1999 Sep 2
PMID 10470468
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Diffuse-type in-stent restenosis (ISR) is associated with higher rate of restenosis after balloon angioplasty, requiring new therapeutic modalities; therefore, it is clinically important to identify the determinants of diffuse-type ISR. We evaluate the clinical and angiographic variables to predict diffuse-type ISR after coronary stent placement. Two hundred and ten ISR lesions in 196 patients (diffuse ISR, 114 lesions; focal ISR, 96 lesions) were reviewed in this study. Clinical, procedural and quantitative coronary angiographic parameters were analyzed. Diffuse-type ISR was defined as a > or = 50% lumen narrowing and > or = 10-mm length. Univariate analysis revealed that initial lesion length, smaller vessel size, diabetes, multivessel disease, multiple stents, and long stent were significantly associated with diffuse-type ISR. However, diabetes was the only independent predictor of diffuse-type ISR by stepwise multiple regression analysis (OR, 3.3; 95% CI, 1.4-7.4, P = 0.001). Diabetes was associated with diffuse-type ISR after coronary stent placement. It may reflect enhanced rate of neointimal hyperplasia within the stent in diabetic patients.

Citing Articles

Risk investigation of in-stent restenosis after initial implantation of intracoronary drug-eluting stent in patients with coronary heart disease.

Xi H, Liu J, Xu T, Li Z, Mou X, Jin Y Front Cardiovasc Med. 2023; 10:1117915.

PMID: 36970340 PMC: 10035367. DOI: 10.3389/fcvm.2023.1117915.


Frequency of recurrence of peripheral artery disease among angioplasty and stenting patients.

Gheini A, Shakarami A, Namdari P, Namdari M, Pooria A Ann Med Surg (Lond). 2021; 72:103146.

PMID: 34925825 PMC: 8649217. DOI: 10.1016/j.amsu.2021.103146.


Factors Affecting In-stent Restenosis in Patients Undergoing Percutaneous Coronary Angioplasty.

Sajadian M, Alizadeh L, Ganjifard M, Mardani A, Ansari M, Falsoleiman H Galen Med J. 2021; 7:e961.

PMID: 34466421 PMC: 8344072. DOI: 10.22086/gmj.v0i0.961.


Predictors of diffuse-type in-stent restenosis following drug-eluting stent implantation.

Park C, Park H Exp Ther Med. 2013; 5(5):1486-1490.

PMID: 23737904 PMC: 3671824. DOI: 10.3892/etm.2013.1024.


Fractional flow reserve for the prediction of cardiac events after coronary stent implantation: results of a multivariate analysis.

Klauss V, Erdin P, Rieber J, Leibig M, Stempfle H, Konig A Heart. 2005; 91(2):203-6.

PMID: 15657233 PMC: 1768692. DOI: 10.1136/hrt.2003.027797.