» Articles » PMID: 10446819

Motor Activity Assessment Scale: a Valid and Reliable Sedation Scale for Use with Mechanically Ventilated Patients in an Adult Surgical Intensive Care Unit

Overview
Journal Crit Care Med
Date 1999 Aug 14
PMID 10446819
Citations 64
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To establish the validity and reliability of a new sedation scale, the Motor Activity Assessment Scale (MAAS).

Design: Prospective, psychometric evaluation.

Setting: Sixteen-bed surgical intensive care unit (SICU) of a 937-bed tertiary care, university-affiliated teaching hospital.

Patients: Twenty-five randomly selected, adult, mechanically ventilated, nonneurosurgical patients who were admitted to the SICU > or = 12 hrs after surgery and were not receiving neuromuscular blockers.

Intervention: Four hundred assessments (eight per patient) were completed consecutively but independently, in pairs, at standardized times (both day and night) by two nurses who were preselected for each assessment from a pool of 32 pretrained SICU nurses.

Measurements And Main Results: To estimate validity, paired assessments (four/patient) compared the MAAS result with the subjective assessment using a 10-cm visual analog sedation scale, the percent change in blood pressure and heart rate from the previous 4-hr baselines, and the number of recent agitation-related sequelae. To estimate reliability, paired assessments (four/patient) measured correlation between assessments of the same type (e.g., MAAS-MAAS). Generalized estimating equations, which accounted for the four repeated measures in each patient, supported MAAS validity by finding a linear trend between MAAS and the visual analog scale (p < .001), blood pressure (p < .001), heart rate (p < .001), and agitation-related sequelae (p < .001) end points. The MAAS (kappa = 0.83 [95% confidence interval, 0.72 to 0.94]) was found to be more reliable than subjective assessment using the visual analog scale (intraclass correlation coefficient = 0.32 [95% confidence interval, 0.05 to 0.55]).

Conclusions: The MAAS is a valid and reliable sedation scale for use with mechanically ventilated patients in the SICU. Further studies are warranted regarding the effect of MAAS implementation in our SICU on patient outcomes, such as quality of sedation and length of mechanical ventilation, as well as the use of the MAAS in other patient populations (e.g., medical).

Citing Articles

Calibration trial of an innovative medical device ( ) for the evaluation of pain in non-communicating patients in the intensive care unit.

Bellal M, Lelandais J, Chabin T, Heudron A, Gourmelon T, Bauduin P Front Med (Lausanne). 2024; 11:1309720.

PMID: 38994344 PMC: 11236545. DOI: 10.3389/fmed.2024.1309720.


Efficacy and Safety of Remimazolam Besylate versus Dexmedetomidine for Sedation in Non-Intubated Older Patients with Agitated Delirium After Orthopedic Surgery: A Randomized Controlled Trial.

Deng Y, Qin Z, Wu Q, Liu L, Yang X, Ju X Drug Des Devel Ther. 2022; 16:2439-2451.

PMID: 35937566 PMC: 9354763. DOI: 10.2147/DDDT.S373772.


Neurological monitoring and sedation protocols in the Liver Intensive Care Unit.

Mehtani R, Garg S, Kajal K, Soni S, Premkumar M Metab Brain Dis. 2022; 37(5):1291-1307.

PMID: 35460476 DOI: 10.1007/s11011-022-00986-7.


The validity, reliability and feasibility of four instruments for assessing the consciousness of stroke patients in a neurological intensive care unit compared.

Yan X, Xiao L, Liao M, Huang J, He Z, Yan T BMC Med Res Methodol. 2022; 22(1):102.

PMID: 35395722 PMC: 8991649. DOI: 10.1186/s12874-022-01580-2.


Short-term effects of endotracheal suctioning in post-cardiac arrest patients: A prospective observational cohort study.

Eggen I, Bronstad G, Langeland H, Klepstad P, Nordseth T Resusc Plus. 2022; 10:100221.

PMID: 35330756 PMC: 8938328. DOI: 10.1016/j.resplu.2022.100221.