The Photon Counting Histogram in Fluorescence Fluctuation Spectroscopy

Overview
Journal Biophys J
Publisher Cell Press
Specialty Biophysics
Date 1999 Jul 2
PMID 10388780
Citations 222
Authors
Affiliations
Soon will be listed here.
Abstract

Fluorescence correlation spectroscopy (FCS) is generally used to obtain information about the number of fluorescent particles in a small volume and the diffusion coefficient from the autocorrelation function of the fluorescence signal. Here we demonstrate that photon counting histogram (PCH) analysis constitutes a novel tool for extracting quantities from fluorescence fluctuation data, i.e., the measured photon counts per molecule and the average number of molecules within the observation volume. The photon counting histogram of fluorescence fluctuation experiments, in which few molecules are present in the excitation volume, exhibits a super-Poissonian behavior. The additional broadening of the PCH compared to a Poisson distribution is due to fluorescence intensity fluctuations. For diffusing particles these intensity fluctuations are caused by an inhomogeneous excitation profile and the fluctuations in the number of particles in the observation volume. The quantitative relationship between the detected photon counts and the fluorescence intensity reaching the detector is given by Mandel's formula. Based on this equation and considering the fluorescence intensity distribution in the two-photon excitation volume, a theoretical expression for the PCH as a function of the number of molecules in the excitation volume is derived. For a single molecular species two parameters are sufficient to characterize the histogram completely, namely the average number of molecules within the observation volume and the detected photon counts per molecule per sampling time epsilon. The PCH for multiple molecular species, on the other hand, is generated by successively convoluting the photon counting distribution of each species with the others. The influence of the excitation profile upon the photon counting statistics for two relevant point spread functions (PSFs), the three-dimensional Gaussian PSF conventionally employed in confocal detection and the square of the Gaussian-Lorentzian PSF for two photon excitation, is explicitly treated. Measured photon counting distributions obtained with a two-photon excitation source agree, within experimental error with the theoretical PCHs calculated for the square of a Gaussian-Lorentzian beam profile. We demonstrate and discuss the influence of the average number of particles within the observation volume and the detected photon counts per molecule per sampling interval upon the super-Poissonian character of the photon counting distribution.

Citing Articles

Quantifying biomolecular organisation in membranes with brightness-transit statistics.

Schneider F, Cespedes P, Karedla N, Dustin M, Fritzsche M Nat Commun. 2024; 15(1):7082.

PMID: 39152104 PMC: 11329664. DOI: 10.1038/s41467-024-51435-1.


Disrupting EGFR-HER2 Transactivation by Pertuzumab in HER2-Positive Cancer: Quantitative Analysis Reveals EGFR Signal Input as Potential Predictor of Therapeutic Outcome.

Ujlaky-Nagy L, Szollosi J, Vereb G Int J Mol Sci. 2024; 25(11).

PMID: 38892166 PMC: 11173106. DOI: 10.3390/ijms25115978.


On-chip microscale isoelectric focusing enhances protein detection limit.

Fan X, Zhang X, Bao H, Zhang X, Ping J Appl Phys Lett. 2024; 124(10):103701.

PMID: 38449998 PMC: 10914402. DOI: 10.1063/5.0190380.


GLUT4 dispersal at the plasma membrane of adipocytes: a super-resolved journey.

Geiser A, Foylan S, Tinning P, Bryant N, Gould G Biosci Rep. 2023; 43(10).

PMID: 37791639 PMC: 10600063. DOI: 10.1042/BSR20230946.


Analysis of photon trajectories from diffusing single molecules.

Gopich I, Kim J, Chung H J Chem Phys. 2023; 159(2).

PMID: 37431909 PMC: 10474944. DOI: 10.1063/5.0153114.


References
1.
BRAUN H, Wissing H, Schafer K, Hirsch M . Oscillation and noise determine signal transduction in shark multimodal sensory cells. Nature. 1994; 367(6460):270-3. DOI: 10.1038/367270a0. View

2.
Borejdo J . Motion of myosin fragments during actin-activated ATPase: fluorescence correlation spectroscopy study. Biopolymers. 1979; 18(11):2807-20. DOI: 10.1002/bip.1979.360181111. View

3.
Palmer 3rd A, Thompson N . High-order fluorescence fluctuation analysis of model protein clusters. Proc Natl Acad Sci U S A. 1989; 86(16):6148-52. PMC: 297794. DOI: 10.1073/pnas.86.16.6148. View

4.
Magde D, Elson E, Webb W . Fluorescence correlation spectroscopy. II. An experimental realization. Biopolymers. 1974; 13(1):29-61. DOI: 10.1002/bip.1974.360130103. View

5.
Koppel D, Axelrod D, Schlessinger J, Elson E, Webb W . Dynamics of fluorescence marker concentration as a probe of mobility. Biophys J. 1976; 16(11):1315-29. PMC: 1334960. DOI: 10.1016/S0006-3495(76)85776-1. View