Intracorneal ring technology has shown rapid development in the past 10 years, and clinical results are confirming outstanding results for the correction of low to moderate refractive myopias. Two of these device designs, the Intrastromal Corneal Ring and the Intrastromal Corneal Ring Segments (both manufactured by KeraVision, Inc., Fremont, CA) are currently undergoing rigorous investigation in US Food and Drug Administration-regulated clinical trials. Results to date indicate the surgical procedure is safe and easily performed, the visual results are excellent (preserving best spectacle-corrected visual acuity), and the procedure provides stable and predictable correction through several years postoperatively. Preliminary results show that enhancements can be easily performed by device exchange, and the device can be removed, reversing the refractive effect.

Citing Articles

Scheimpflug-Derived Corneal Lower and Higher Order Aberrations Post Intrastromal Corneal Ring Segments for Keratoconus.

van den Berg R, van den Berg A, Dodhia M, Shahid M, Jammal A, de Freitas D Vision (Basel). 2022; 6(4).

PMID: 36548938 PMC: 9784986. DOI: 10.3390/vision6040076.


Innovative intra-corneal ring-supported graft surgery for treatment of keratoconus and cornea regeneration: Surgical technique and case report.

Jadidi K, Mosavi S, Nejat F, Aghamolaei H, Pirhadi S Indian J Ophthalmol. 2022; 70(9):3412-3415.

PMID: 36018132 PMC: 9675543. DOI: 10.4103/ijo.IJO_2962_21.


Morphological characterization and clinical effects of stromal alterations after intracorneal ring segment implantation in keratoconus.

Hamon L, Schlotzer-Schrehardt U, Flockerzi F, Seitz B, Daas L Graefes Arch Clin Exp Ophthalmol. 2022; 260(7):2299-2308.

PMID: 35106630 PMC: 9203383. DOI: 10.1007/s00417-022-05572-2.


Combined Corneal Cross-Linking and Myoring Implantation in Advanced Keratoconus: Femtosecond Laser versus Manual Dissection.

Basiony A, Fayez Elsawy M, Mohamed Ismail M, Samy Abd Elaziz M, KhalafAllah M, Galal Zaky A J Ophthalmol. 2021; 2021:6673842.

PMID: 34513086 PMC: 8428991. DOI: 10.1155/2021/6673842.


Effect of Sequential Intrastromal Corneal Ring Segment Implantation and Corneal Collagen Crosslinking in Corneal Ectasia.

Kim C, Kim M Korean J Ophthalmol. 2019; 33(6):528-538.

PMID: 31833250 PMC: 6911792. DOI: 10.3341/kjo.2019.0088.