» Articles » PMID: 10352609

Diffusion-weighted Imaging with Navigated Interleaved Echo-planar Imaging and a Conventional Gradient System

Overview
Journal Radiology
Specialty Radiology
Date 1999 Jun 3
PMID 10352609
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To demonstrate the technical feasibility and precision of a navigated diffusion-weighted (DW) MR imaging method with interleaved echo-planar imaging and test its diagnostic sensitivity for detection of ischemic stroke.

Materials And Methods: Apparent diffusion coefficient (ADC) measurements were performed in phantoms, and six healthy adult volunteers were examined to determine intrasubject (precision) and intersubject (reference range) variations in absolute ADC and relative ADC (rADC) measurements. DW imaging maps and lesion rADC values were also obtained in 34 consecutive stroke patients to evaluate the sensitivity and reliability of DW-interleaved echo-planar imaging for detection of ischemic brain damage.

Results: Phantom and volunteer ADC values were in excellent agreement with published data. The intrasubject variation of rADC was 6.2%. The ADC precision ranged from 6.5% in the subcortical white matter in the frontal lobe to 12.9% in the head of the caudate nucleus. Interleaved echo-planar imaging enabled rapid acquisition of high-quality images of the entire brain without substantial artifacts. Within the 1st week, the sensitivity of DW-interleaved echo-planar imaging for detection of acute infarction was 90% (18 of 20 true-positive studies) and independent of lesion location.

Conclusion: DW-interleaved echo-planar imaging with phase navigation and cardiac triggering is robust, reliable, and fast. With high sensitivity for detection of early ischemic infarction, it is useful for examining stroke patients by using MR systems with conventional gradient hardware.

Citing Articles

Evaluating drug distribution in children and young adults with diffuse midline glioma of the pons (DIPG) treated with convection-enhanced drug delivery.

Szychot E, Bhagawati D, Sokolska M, Walker D, Gill S, Hyare H Front Neuroimaging. 2023; 2:1062493.

PMID: 37554653 PMC: 10406269. DOI: 10.3389/fnimg.2023.1062493.


Water/fat separation for self-navigated diffusion-weighted multishot echo-planar imaging.

Dong Y, Riedel M, Koolstra K, van Osch M, Bornert P NMR Biomed. 2022; 36(1):e4822.

PMID: 36031585 PMC: 10078174. DOI: 10.1002/nbm.4822.


Posterior reversible encephalopathy syndrome mimicking subacute ischemic stroke: a case report.

Yamaguchi S, Endo H, Hiratsuka Y, Nakamura H Radiol Case Rep. 2022; 17(9):3071-3074.

PMID: 35769122 PMC: 9234533. DOI: 10.1016/j.radcr.2022.06.013.


High-Spatial-Resolution Multishot Multiplexed Sensitivity-encoding Diffusion-weighted Imaging for Improved Quality of Breast Images and Differentiation of Breast Lesions: A Feasibility Study.

Daimiel Naranjo I, Gullo R, Morris E, Larowin T, Fung M, Guidon A Radiol Imaging Cancer. 2021; 2(3):e190076.

PMID: 33778712 PMC: 7983772. DOI: 10.1148/rycan.2020190076.


Development of a novel phantom using polyethylene glycol for the visualization of restricted diffusion in diffusion kurtosis imaging and apparent diffusion coefficient subtraction method.

Khasawneh A, Kuroda M, Yoshimura Y, Sugianto I, Bamgbose B, Hamada K Biomed Rep. 2020; 13(6):52.

PMID: 33082949 PMC: 7557516. DOI: 10.3892/br.2020.1359.