Background: Factor V Leiden (G1691A) is a common cause of inherited thrombosis. In fluorescent melting curve analysis, the Leiden mutation is distinguished from the wild-type by a decrease in melting temperature (Tm) of a wild-type probe. Because Tm depends on the type and position of the mismatch, other base alterations, such as the recently described base alteration A1692C, should be distinguishable from the true Leiden mutation. Methods and Results: Of 2,100 samples tested for the factor V Leiden mutation using a wild-type probe, 200 heterozygous or homozygous mutant samples were further tested using a Leiden probe. The Tm of the A1692C base alteration was 1.5 degrees C greater than the Leiden mutation with the wild-type probe and 8 degrees C less with the Leiden probe. One sample was heterozygous for a new base alteration G1689A with a Tm 0.8 degrees C greater than the Leiden mutation with the wild-type probe, and 10 degrees C less with the Leiden probe. Tm estimates from fluorescence melting curve analysis have intra-assay standard deviations of approximately 0.1 degrees C. Conclusions: Fluorescence melting curve analysis can distinguish between sequence alterations with Tms differing by less than 1 degrees C. This is the first demonstration of a widely applicable technique that can significantly increase the specificity of hybridization techniques without the need for sequencing.

Citing Articles

Testing for Factor V Leiden (FVL) and Prothrombin G20210A Genetic Variants.

Pajic T Methods Mol Biol. 2023; 2663:233-251.

PMID: 37204714 DOI: 10.1007/978-1-0716-3175-1_14.


Mutation spectrum of COL1A1/COL1A2 screening by high-resolution melting analysis of Chinese patients with osteogenesis imperfecta.

Ju M, Bai X, Zhang T, Lin Y, Yang L, Zhou H J Bone Miner Metab. 2019; 38(2):188-197.

PMID: 31414283 DOI: 10.1007/s00774-019-01039-3.


Simultaneous detection, genotyping, and quantification of human papillomaviruses by multicolor real-time PCR and melting curve analysis.

Liao Y, Zhou Y, Guo Q, Xie X, Luo E, Li J J Clin Microbiol. 2012; 51(2):429-35.

PMID: 23175255 PMC: 3553893. DOI: 10.1128/JCM.02115-12.


LightCycler technology in molecular diagnostics.

Lyon E, Wittwer C J Mol Diagn. 2009; 11(2):93-101.

PMID: 19196999 PMC: 2665858. DOI: 10.2353/jmoldx.2009.080094.


Robustness of single-base extension against mismatches at the site of primer attachment in a clinical assay.

Kirsten H, Teupser D, Weissfuss J, Wolfram G, Emmrich F, Ahnert P J Mol Med (Berl). 2006; 85(4):361-9.